Effect of various storage times for a block sample. Experiences with sample tubes coated with a low friction polymer and a new piston sampler, all on Onsøy clay
Report
Permanent lenke
http://hdl.handle.net/11250/2560292Utgivelsesdato
2017-11-08Metadata
Vis full innførselSamlinger
- NGI report [198]
Sammendrag
This report contains the results of four CAUC triaxial tests, two being performed on
block samples and two on 72 mm tube samples. The tests were all performed on plastic
clay from Onsøy.
The purpose with the block samples was to see if there is any significant improvement
in sample quality whether the sample is mounted into the triaxial in the field compared
to when it is transported to the laboratory and mounted into the triaxial cell several days
later. However, no improvement was observed in sample quality for the test on the
sample being mounted in the field.
One of the two tube samples was sampled with the ordinary NGI 72 mm piston sampler,
but the sample tube was smeared on the inside and the outside with a low friction
polymer. However, again, no improvement in sample quality.
The other tube (72 mm) sample was sampled with a new piston sampler for a remote
operated drilling system (Santos et al, 2015). However, during removal of the sample
tube from the sampler a suction was created that spoiled the sample so no conclusion
can be drawn regarding this sampler in this case